"Efficacy of low-dose intra-articular tranexamic acid in total knee replacement; a prospective triple-blinded randomized controlled trial
ปพน สง่าสูงส่ง, Siwadol Wongsak, Pongsthorn Chanplakorn, ภัทรวัณย์ วรธนารัตน์, Supaporn Wechmongkolgorn, Bussanee Wibulpolprasert, Pornchai Mulpruek, วิโรจน์ กวินวงศ์โกวิท*
"Department of Orthopedics, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, 270, Rama VI Road, Ratchathewi, Bangkok, Thailand 10400; E-mail: viroj.k2009@yahoo.com
บทคัดย่อ
Background: Recently, a number of studies using intra-articular application of tranexamic acid (IA-TXA), with different dosage and techniques, successfully reduced postoperative blood loss in total knee replacement (TKR). However, best of our knowledge, the very low dose of IA-TXA with drain clamping technique in conventional TKR has not been yet studied. This study aimed to evaluate the effectiveness and dose-response effect of two low-dose IA-TXA regimens in conventional TKR on blood loss and blood transfusion reduction.
Methods: Between 2010 and 2011, a triple-blinded randomized controlled study was conducted in 135 patients undergoing conventional TKR. The patients were allocated into three groups according to intra-articular solution received: Control group (physiologic saline), TXA-250 group (TXA 250 mg), and TXA-500 group (TXA 500 mg). The solution was injected after wound closure followed by drain clamping for 2 hours. Blood loss and transfusion were recorded. Duplex ultrasound was performed. Functional outcome and complication were followed for one year.
Results: There were forty-five patients per groups. The mean total hemoglobin loss was 2.9 g/dL in control group compared with 2.2 g/dL in both TXA groups (p > 0.001). Ten patients (22%, control), six patients (13%, TXA-250) and none (TXA-500) required transfusion (p = 0.005). Thromboembolic events were detected in 7 patients (4 controls, 1 TXA-250, and 2 TXA-500). Functional outcome was non-significant difference between groups.
Conclusions: Combined low-dose IA-TXA, as 500 mg, with 2-hour clamp drain is effective for reducing postoperative blood loss and transfusion in conventional TKR without significant difference in postoperative knee function or complication.
 
 
ที่มา
Bmc Musculoskeletal Disorders ปี 2556, December ปีที่: 14 ฉบับที่ 340 หน้า
คำสำคัญ
Intra-articular tranexamic acid, Blood loss reduction, Blood transfusion reduction, Clamp drain technique